Heat Controller 30 Out of 5 Stars 2 Reviews Heat Controller Psh-141a Room Portable Air
Comfort Aire AC Error Codes
Some bug tin can exist resolved without whatever maintenance to the unit, check the chart below to see if there is a suggested solution to the problem before calling for service.
Glossary of Error Codes and Their Meanings:
Error Codes | Meaning |
---|---|
E1 | High Pressure level Protection |
E2 | Shutdown for Whole Unit of measurement AntiFreeze Protection |
E3 | Low Pressure level Protection |
E4 | High Belch Temp Protection |
E6 | Communication Mistake |
E9 | Indoor Unit of measurement Water Full Error |
Fo | Refrigerant Recovery Fashion |
F3 | Outdoor Ambient Temp Sensor Error |
F4 | Outdoor Mid-Whorl Temp Sensor Error |
F5 | Outdoor Discharge Air Temp Sensor Mistake |
F7 | Oil Return for Cooling |
H1 | Forced Defrosting |
H2 | Oil Render for Heating or Defrosting |
H3 | Compressor Overheat Protection |
H5 | IPM Protection |
H7 | Motor Desynchronizing |
Hc | PFC Error |
Lc | Startup Failure |
LA | DC Fan motor Fault |
Ld | Phase Loss |
LE | Compressor Stalling |
LF | Over-Speed |
P0 | IPM Reset |
P5 | Compressor Current Protection |
P6 | Communication Error betwixt the Inverter Drive and the Main Controller |
P7 | Radiator Temp Sensor Error |
P8 | Radiator Overheat Protection |
P9 | Ac Contactor Protection |
Pc | Current Sensor Error |
Pd | Sensor Connection Protection |
PH | Over Voltage Protection |
PL | Depression Voltage Protection |
PE | Temp Drift Protection |
PF | Drive Board Ambience Temp Sensor Error |
PA | Ac Electric current Protection |
PU | Charging Circuit Error |
PP | AC Input Voltage Anomaly |
Troubleshooting
Before calling for service, review this list. It may salve you time and expense. This list includes common occurrences that are non the upshot of defective workman-ship or materials in this appliance.
Problem: The unit will not operate at all.
Cause:
- Blown Fuse or tripped circuit billow
- Power Failure
- Remote Command batteries are depression
- Signal from remote control is not being sent
Solution:
- Check the fuse or excursion breaker. Supercede the diddled fuse or reset the circuit breaker.
- Expect until the power is restored to restart the unit. If you experience brown out atmospheric condition, contact an electrician or your local utility.
- Replace the batteries. Be sure not to mix old and new batteries, as well as different brands/types
- Be sure that yous are not using the remote control likewise far away from the indoor unit's control panel.
Problem: The unit runs and and so stops immediately
Crusade: Air inlets and/or outlets are blocked
Solution: Remove whatever obstacles from the air inlets/outlets/Make clean the air filter, louvers, and inlet grille.
Problem: Abnormal heating or cooling
Cause:
- Air inlets and/or outlets are blocked
- Improper temperature is set
- Check the fan speed
- Improper louver aligning
- Exist certain that there are no other sources of heat/steam in the area beingness cooled
- Conditioned air might exist escaping
Solution:
- Remove any obstacles from the air inlets/outlets-Clean the air filter, louvers, and inlet grille.
- Ensure that the proper fashion and temperature is assault the unit. Endeavor to adjust the set point temperature on the thermostat to a better operating temperature
- Accommodate the fan speed to see if that improves the atmospheric condition.
- Endeavor to adjust the louver position to ensure it is open plenty.
- Remove or turn off other appliances producing heat or steam.
- Ensure that any doors or windows in the area existence heated/cooled are closed
Problem: Air from unit does not feel cold plenty
Solution:
- Room temperature below 62 F(17 C ). Cooling may not occur until room temperature O O rises above 62 F(17 C).
- Temperature sensing behind air filter chemical element touching cold coil. Go along it from the cold curlicue.
- Set to a Lower temperature.
- Compressor stopped when irresolute modes. Expect for 3 minutes subsequently set to the Cool way.
Problem: Dissonance when unit is cooling
Solution:
- Air movement sound. This is normal . If likewise loud, set to a slower FAN setting.
- Window vibration – poor installation. Refer to installation instructions or cheque with installer.